Installation Instructions

ELECTRICAL CONNECTION
INFORMATION

WARNING –

To reduce the risk

of fire, electrical shock and personal injury:

The water heater must be electrically grounded
in accordance with local codes and ordinances
or, in the absence of local codes, in accordance
with the NATIONAL ELECTRICAL CODE, ANSI/NFPA
NO. 70, or the CANADIAN ELECTRICAL CODE,
CSA C22.1.

ELECTRICAL REQUIREMENTS

This appliance must be supplied with 120V, 60Hz,
and connected to a properly grounded branch
circuit, protected by a 15- or 20-amp circuit
breaker or time-delay fuse.

If electrical supply provided does not meet the
above specifications, it is recommended that a
licensed electrician install an approved outlet.

4

PCB

GROUND

TERMINAL

120VAC CONNECTION WIRES

(Black-Hot/White-Neutral)

Wire nuts

Inside unit

Electrical
disconnect
switch

Electrical
connection

Outside unit