Using FPC 1000 with a Notebook PC

Card Problems

Possible Causes

Suggestions

Unsuccessful
driver installation.

An ft1000clean.exe utility is provided on
the distribution CD under the Tools
directory to resolve unsuccessful driver
installation.

The blue light
(LED) on the side
of the PC card fails
to illuminate after
driver installation,
OR "Driver
Installation Error"
message displays
after software
installation.

Use the following procedure to resolve the
above problems during a

:

full installation

1. Eject the PC card from the system.
2. Uninstall the software package via

My Computer→Control
Panel→Add/Remove
Programs→Flarion Mobility
Manager →Change/Remove.

3. Run ft1000clean.exe (located on the

distribution CD under the Tools
directory).

4. Reboot the system as instructed by

the ft1000clean.exe utility.

5. Reinstall the software package

following the normal installation
procedure.

For an upgrade installation:

1. Eject the PC card from the system.
2. Run ft1000clean.exe (located on the

distribution CD under the Tools
directory).

3. Reboot the system as instructed by

the ft10000clean.exe utility.

4. Run Upgrade.exe located under the

'UpgradeCache' directory in the
Flarion Mobility Manager folder.

5. Select "yes" when prompted by

Upgrade.exe to repair the current
Flarion Mobility Manager.

6. Insert the PC card after completion of

Upgrade.

2004 Flarion

Version 1.0

Flarion Proprietary and Confidential

Page 37

Advertising