Installation instructions, Ductwork length and duct fittings – GE JVB37 User Manual

Page 13

Advertising
background image

Installation Instructions

13

DUCTWORK LENGTH AND DUCT FITTINGS

NOTE: Do not exceed 150 foot maximum permissible equivalent lengths!

Flexible ducting: If flexible metal ducting is used, all equivalent feet values in the table should be
doubled. The flexible metal duct should be straight and smooth and extended as much as possible.

DO NOT use flexible plastic ducting.

Add equivalent lengths for all duct pieces and transitions used to ensure that the duct run does not
exceed the maximum 150 feet.

Duct Equivalent Duct Equivalent Duct Equivalent

Pieces

Length*

Pieces

Length*

Pieces

Length*

3

1

4

″ x 10″

to 6

″ Round

6

″ Round

1 ft. (per

3

1

4

″ x 10″

Transition

4 ft.

Straight

foot length)

45° Elbow

8 ft.

90° Elbow

6

″ Round

3

1

4

″ x 10″

1 ft. (per

3

1

4

″ x 10″

Wall Cap

24 ft.

Straight

foot length)

90° Flat Elbow

33 ft.

with Damper

6

″ Round

3

1

4

″ x 10″

6

12 ft.

to 3

1

4

″ x 10″

2 ft.

Wall Cap

24 ft.

90° Elbow

Transition

with Damper

3

1

4

″ x 10″

6

to 6

″ Round

2 ft.

6

″ Round

45° Elbow

7 ft.

Transition

Roof Cap

33 ft.

6

″ Round

to 3

1

4

″ x 10″

3

1

4

″ x 10″

Transition

4 ft.

90° Elbow

14 ft.

90° Elbow

SHOULD NOT EXCEED 150 EQUIVALENT FEET

*Equivalent lengths of duct pieces are based on actual tests conducted by GE Evaluation Engineering

and reflect requirements for good venting performance. See chart for CFM Duct Length.