Power supply – GE JVB37 User Manual

Page 12

Advertising
background image

12

Installation Instructions

INSTALLING THE DOWNDRAFT VENT SYSTEM

POWER SUPPLY

This downdraft vent must be supplied with
120V, 60Hz., and connected to an individual,
properly grounded branch circuit, protected
by a 15 or 20 ampere circuit breaker or time
delay fuse.

Gas Cooktops
If this vent is installed in combination with a
gas cooktop, it may operate from the same
duplex outlet.

Electric Cooktops
If this vent is installed in combination with an
electric cooktop, the vent must operate from
a separate 120V outlet.

A properly grounded 3-prong receptacle
should be located within reach of the vent’s
2 foot power cord.

Locate the receptacle inside the cabinet on

the right side wall. The receptacle cannot
be placed on the back of the cabinet wall
where it may interfere with the downdraft
plenum. See illustration.

NOTE: Do not use an extension cord or
adapter plug with this appliance. Follow
National electrical codes or prevailing local
codes and ordinances.