Introduction, Electrical specifications continued – Garland E24-72G User Manual

Page 6

Advertising
background image

Part # 1009080 Rev 4 (01/25/08)

Page 6

INTRODUCTION

Your new equipment should be given regular care and

maintenance . Periodic inspections by your dealer or a

qualified service agency are recommended .

This product has been certified as commercial cooking

equipment and must be installed by professional personnel

as specified .

Rating Plate

When corresponding with the factory or your local

authorized factory service center regarding service problems

or replacement parts, be sure to refer to the particular unit

by the correct model number (including the prefix and suffix

letters and numbers) and the warranty serial number . The

rating plate affixed to the unit contains this information . The

rating plate is located on the main back panel behind the

unit, on hot plates . For griddles the plate is located on the

grease drawer slide, remove the grease drawer to access .

Before attempting the electrical connection, the rating

pate should be checked to ensure that the unit’s electrical

characteristics and the supply characteristics agree .

LOADING CHART E24-H Hot Plate

Model

Total Kw

Load

Nominal Amperes Per Line

3 Phase

Single Phase

240V

208V

240V

208V

X

Y

Z

X

Y

Z

E24-12H

4 .2

15 .2

8 .8

8 .8

17 .5

10 .1

10 .1

17 .5

20 .2

Export voltage available on request – Specify wiring required

kW loadings are reduced on 220 volt systems .

Standard wiring 240 volt (220/240) or 208 volt (197/219) single or three phase

ELECTRICAL SPECIFICATIONS Continued

Advertising