Installation – Garland E24-72G User Manual

Page 7

Advertising
background image

Part # 1009080 Rev 5 (01/25/08)

Page 7

INSTALLATION

Unpacking

Unpack units carefully and provide the necessary space on

counter of back bar . All units must be installed following the

minimum back and side clearances stated on the tag affixed

to each individual unit . To insure proper field wiring size

check tag attached to the rear of the unit near knockout .

Leg Installation

1 . All units are shipped with N .S .F . approved legs . These

legs must be installed to provide a minimum clearance

of 4” (102mm) between he counter top and bottom of

the appliance in order to meet the National Sanitation

Foundation requirements .

2 . When using the legs described above, raise the front of

the appliance and screw the leg into the leg-retaining nut

provided at each corner of the appliance, repeat at each

rear .

 . The unit may be leveled by adjusting the legs . Use a spirit

level and level the appliance four (4) ways: across the

front and back; and down left and right edges .

NOTE: Griddles may not rest evenly on the appliance body if

the appliances are not leveled .

Electrical Connections

Before attempting the electrical connection, the rating

plate should be checked to ensure that the unit’s electrical

characteristics and the supply characteristics agree .

Installation of the wiring must be made in accordance with

UL 197 Commercial Electric Cooking Appliance Standards,

Local and/or National Electrical Code, and ANSI/NFPA 70-

1990 and include .

1 . Switch panel size

2 . Overload protection

 . Wire type

4 . Wire size

5 . Temperature limitations of the wires

6 . Method of connection (Cable, Conduit, etc .)

The service line enters though the rear of the unit and is

to be connected to the terminal block . Input voltage and

phasing must match the unit’s voltage and phasing .

Visually check all electrical connections .

Energize the electrical connections .

NOTE: Appliances are not internally fused . They must be

connected to a suitable disconnect box in accordance with

local code .

E24-12H Hot Plate

Electrical connection to the terminal may be made though

the knockout on the main back . Front access is gained by

raising the rear surface element and removing bowl . The

terminal block shield is located toward the back lower left of

the unit .

E24 Series Griddles

The electrical connections may be made though the

knockout at the rear of the unit to the terminal block located

behind the terminal block shield .

Front access is gained by raising and propping the griddle

plate . The terminal block shield is toward the back and left

of the appliance . Remove the shield to expose the terminal

block . Make the necessary connection and replace the shield .

These appliances have no fusing .

Advertising