Operation continued – Garland E24-72G User Manual

Page 9

Advertising
background image

Part # 1009080 Rev 5 (01/25/08)

Page 9

Calibration of the Griddle Thermostat

Equipped with commercial duty snap action electric

thermostats, these units are designed to open on

temperature rise . Field re-calibration is seldom necessary and

should not be resorted to unless experience with cooking

results definitely proves that the control is not maintaining

the temperature to which the dial is set .

NOTE: NO ATTEMPT TO RECALIBRATE THE GRIDDLE CONTROL

SHOULD BE MADE WITHIN THE WARRANTY PERIOD . IF

THE CONTROL IS OUT ± 20° F FROM THE DIAL SETTING,

THE CONTROL WILL BE REPLACES UNDER WARRANTY .

IF SOMEONE ATTEMPTS RECALIBRATION DURING THE

WARRANTY PERIOD THERE WILL BE NO WARRANTY ON THE

CONTROL THAT WAS TAMPERED WITH .

Calibration Instructions

1 . Use a test instrument (surface pyrometer) with a special

disc type thermocouple or reliable “surface” type

thermometer . Note: A drop of oil on the face of the disc

will provide better contact with the griddle plate .

2 . Turn all griddle thermostats to 50° F (177° C) . In order

to allow the griddle temperature to stabilize the controls

must be allowed to cycle three times before taking a test

reading .

 . Check the temperature reading when the thermostat

cycles off by placing the sensor firmly on the center

of each section of the griddle surface . Take a second

temperature reading when they thermostat cycles back

on . Make a note of this reading . The average of the two

readings should be ± 20° of 50° set temperature .

If the average is more than the 20° tolerance, recalibrate

as follows .

OPERATION Continued

4 . Carefully remove the thermostat dial, not disturbing the

dial setting .

5 . Hold the dial shaft steady and with a screwdriver turn the

calibration screw, (that is located inside the thermostat

shaft), clockwise to decrease and counter-clockwise to

increase the temperature . A 1/4 turn = 25°F change

6 . Replace the thermostat dial and repeat steps 1 through 

to verify if the correct adjustment has been made .

Dial Shaft

Calibration Screw Head

Calibration

Screw Head

Increase

Decrease

1/4" Turn

Advertising