Installation instructions, Installing the cooktop, C1 c3 – GE JGP321 User Manual

Page 18: Install the regulator onto the burner box bottom

Advertising
background image

C1

C3

18

Installation Instructions

This cooktop is designed to operate on natural
gas at 4

″ of water column pressure. It is

shipped from the factory set for natural gas
(except JGP319 models, which are set for LP).
The convertible pressure regulator supplied
with the unit must be connected in series with
the manifold of the cooktop and must remain
in series with the supply line regardless of
whether natural or L.P. gas is being used.
FOR PROPER OPERATION, THE MAXIMUM
INLET PRESSURE TO THE REGULATOR
MUST BE NO MORE THAN 14

″ OF WATER

COLUMN PRESSURE. For checking the
regulator, the inlet pressure must be at least
1

″ (or 3.4 KPA) greater than the regulator

output setting. If the regulator is set for 4

″ of

water column pressure, the inlet pressure
must be at least 5

″. If the regulator is set for

10

″, the inlet pressure must be at least 11″.

The gas supply line to the cooktop should be
1/2

″ or 3/4″ pipe.

Provide Adequate Gas
Supply

Installing the Regulator

WARNING: Never reuse old flexible
connectors. The use of old flexible
connectors can cause gas leaks and
personal injury. Always use new
flexible connectors when installing
a gas appliance.

Screw a section of pipe
onto each end of the
pressure regulator.

C4

Install the regulator onto
the burner box bottom

Pressure

Regulator

Shut Off

Valve

Electrical

Outlet

12" Below

Countertop

Screw the
regulator and
pipe connection
into the burner
box bottom.
Make sure the
top of the
regulator is
facing toward
the cabinet front,
easily accessible
through the
cabinet doors.

NEVER REUSE OLD CONNECTORS
WHEN INSTALLING THIS COOKTOP.

To reduce the likelihood of gas leaks, apply
teflon tape or a thread compound approved
for use with LP or natural gases to all
threaded connections.

Pressure

Regulator

Installing the Cooktop

C

C2

Locate the electrical outlet
and the Gas Shut Off valve
beneath the cabinet.

Shut Off

Valve

Electrical

Outlet

12" Below

Countertop

Install a manual shutoff valve in the gas line
in an easily accessible location outside the
cooktop. Be sure you know how and where to
shut off the gas supply to the cooktop. Install
the electrical outlet 12

″ below the countertop.

NEVER REUSE
OLD CONNECTORS
WHEN INSTALLING
THIS UNIT.

Advertising