Warning, Electrical connection - u.s.a. only – Maytag W10099070 User Manual

Page 9

Advertising
background image

9

Electrical Connection - U.S.A. Only

Power Supply Cord

Direct Wire

1. Disconnect power.

2. Remove the hold-down screw and terminal block cover.

3. Install strain relief.

Style 1: Power supply cord strain relief

Remove the screws from a

³⁄₄" (1.9 cm) UL listed strain

relief (UL marking on strain relief). Put the tabs of the two
clamp sections into the hole below the terminal block
opening so that one tab is pointing up and the other is
pointing down, and hold in place. Tighten strain relief
screws just enough to hold the two clamp sections
together.

Put power supply cord through the strain relief. Be sure
that the wire insulation on the power supply cord is inside
the strain relief. The strain relief should have a tight fit with
the dryer cabinet and be in a horizontal position. Do not
further tighten strain relief screws at this point.

WARNING

Fire Hazard

Use a new UL listed 30 amp power supply cord.

Use a UL listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center
terminal (silver).

Ground wire (green or bare wire) must be connected to
green ground connector.

Connect remaining 2 supply wires to remaining
2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or
electrical shock.

WARNING

Fire Hazard

Use 10 gauge solid copper wire.

Use a UL listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center
terminal (silver).

Ground wire (green or bare wire) must be connected to
green ground connector.

Connect remaining 2 supply wires to remaining
2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or
electrical shock.

A. Neutral ground wire

B. External ground conductor screw

C. Center, silver-colored terminal block screw
D. Terminal block cover and hold-down screw

A

B

C

D

A. Strain relief tab pointing up
B. Hole below terminal block opening

C. Clamp section
D. Strain relief tab pointing down

A

B

C

D

Advertising