P R O B L E M

POSSIBLE CAUSE(S)

S O L U T I O N

APS Custom does not play
the re c o rded user name
when the associated
extension is enter e d .

User name has not been

re c o rd e d .

•Enter programming mode and

re c o rd specified User Name.
See user manual figure 3-11.

Wrong connection type

s e l e c t e d .

A P S Custom PCI modem not

p o w e red up or phone line not

connected to modem.

APS Custom unit was

powered up prior to

connecting modem to the

APS Custom unit.

I n c o rrect cable connecting

A P S Custom unit to the

modem or modem is

connected to the wrong port

on the APS Custom Unit.

I n c o rrect dipswitch settings on

modem connected to the APS

Custom unit.

Modem connected to the APS

Custom unit is not powere d

up or phone line not

c o n n e c t e d .

A P S Custom unit is busy (i.e.,

callers are actively connected

to the unit).

•Exit APS Custom PCI and

verify the correct modem is
selected in the Procomm Plus
t e rminal window.

•Verify power and phone line

connections to the APS
Custom PCI modem.

•Power down the APS Custom

unit and the modem connected
to APS Custom unit, then
power up the modem and then
the APS Custom unit.

•Verify the cable connecting the

A P S Custom unit to the
modem is a 9 pin female to 25
pin male modem cable and is
connected to the PCI/Modem
p o rt on the APS Custom unit.

•Verify dipswitches 1, 4, 6, and

7 are in the up position and 2,
3, 5, and 8 are in the down
p o s i t i o n .

•Verify phone is connected. If

modem was not powered up,
power down the APS Custom
unit, then power up the
modem and then power up the
APS Custom unit.

•E n s u re callers are not accessing

the APS Custom unit during
the connection attempt.

Advertising