BLW-400SSW-WELDER/AC GENERATOR— PARTS & OPERATION MANUAL— REV. #1 (06/15/01) — PAGE 35

BLW-400SSW — SHUTDOWN INSTRUCTIONS

Shutdown

1. Switch the circuit breakers to ‘OFF’ position (Figure 28.

2. Switch the Idle Control switch to ‘OFF’ position (Figure

29). Let engine run for 5 minutes in idle mode.

3. Turn the key switch to ‘STOP’ position (Figure 30).

4. Remove welding apparatus and output terminal loads

from welder/generator set.

5. Turn the fuel cock to closed position.

Emergency Shut-Down

To stop during an emergency, turn the key switch to ‘STOP’

position.

CAUTION :

Do not shut down the welder/generator set
by shutting off the engine except in an
emergency.

Figure 28. Main and receptacle circuit breakers

Figure 29. Idle Control Switch

Figure 30. Key switch set to ‘STOP’ position