Smudges and dirt can interfere with the proper scanning of a bar code.
Therefore, the output window will need occasional cleaning.
For the MS7600 glass window:
1. Spray glass cleaner onto lint free, non-abrasive cleaning cloth.
2. Gently wipe the scanner window.
For the MS7600 red window:
1. Use mild soap and water with lint free, non-abrasive cleaning cloth.
2. Gently wipe the scanner window.
EAS D
EACTIVATION
A
NTENNA
SW1 and SW2 are the switch banks inside the Checkpoint Device that set the
deactivation range. Metrologic recommends end users program the MS7600 to
the Fixed Low-Density depth of field, so that the unit does not scan out beyond
the deactivation range.
Unit #
CheckPoint Recommended
Switch Bank Settings
MS7600 Depth of Field
Settings
MS7620
1, 2, 3, 4, 5, on SW1 & SW2
Fixed Low Density*
MS7625
1, 2, 3, 4, 5, on SW1 & SW2
Fixed Low Density*
*Note: Minimum element width changes to 6.8 mil when in this mode.
Figure 22: EAS Cable and Connector
Contact Checkpoint Systems directly for additional EAS support.
EAS Cable
Connector
EAS Cable
MLPN