36

D

ESIGN

S

PECIFICATIONS

(C

ONTINUED

)

MS7600 S

ERIES

D

ESIGN

S

PECIFICATIONS

E

LECTRICAL

Input Voltage:

5.2VDC ± 0.25V

Power:

2.6 W

Operating Current:

500 mA

Laser Off Power Save Mode = < 350 mA

Standby Current:

Laser/Motor Off Power Save Mode = <165 mA

DC Transformers:

Class II; 5.2 V @ 650 mA

Laser Class:

IEC 60825-1:1993+A1:1997+A2:2001 Class 1

EMC:

FCC, ICES-003 & EN 55022 Class B

E

NVIRONMENTAL

Operating Temperature:

0°C to 40°C (32°F to 104°F)

Storage Temperature:

-40°C to 60°C (-40°F to 140°F)

Humidity:

5% to 95% relative humidity, non-condensing

Light Levels:

4842 LUX (450 foot candles)

Contaminants:

Sealed to resist airborne particulate contaminants

Ventilation:

None required

Specifications subject to change without notice.