4-7. Remote 14 Receptacle Information

Socket*

Socket Information

24 VOLTS AC

A

24 volts ac. Protected by circuit breaker CB2.

A

J

B

K

I

24 VOLTS AC

B

Contact closure to A completes 24 volts ac

contactor control circuit.

B

K

I

C L N

H

115 VOLTS AC

I

115 volts ac. Protected by circuit breaker CB1.

C

N

H

D M

G

E

F

115 VOLTS AC

J

Contact closure to I completes 115 volts ac

contactor control circuit.

C

Output to remote control; 0 to +10 volts dc, +10

volts dc in MIG mode.

REMOTE

OUTPUT

D

Remote control circuit common.

OUTPUT

CONTROL

E

0 to +10 volts dc input command signal from

remote control.

M

CC/CV select

A/V

F

Current feedback; +1 volt dc per 100 amperes.

A/V

AMPERAGE

VOLTAGE

H

Voltage feedback; +1 volt dc per 10 output recep-

tacle volts.

GND

G

Circuit common for 24 and 115 volts ac circuits.

GND

K

Chassis common.

*The remaining sockets are not used.

803 691-C

1

115 V 10 Amp AC Receptacle

Power is shared between duplex

receptacle and Remote 14 recep-

tacle (see Section 4-7).
2

Circuit Breaker CB1

3

Circuit Breaker CB2

CB1 protects duplex receptacle

and 115 volts ac portion of Remote

14 receptacle from overload.
CB2 protects 24 volts ac portion of

Remote 14 receptacle from

overload.
Press button to reset breaker.

2

3

1

4-8. Optional 115 Volts AC Duplex Receptacle And Circuit Breakers