4. lift-arc tig procedure, 5. stick start procedure – Miller Electric EXTREME 360 User Manual

Page 26

Advertising
background image

OM-229 409 Page 22

5-4. Lift-Arc TIG Procedure

With Process Switch in the Lift-Arc

TIG position, start an arc as follows:
1

TIG Electrode

2

Workpiece

Touch tungsten electrode to work-

piece at weld start point, hold

electrode to workpiece for 1-2

seconds, and slowly lift electrode.

An arc will form when electrode is

lifted.
Normal open-circuit voltage is not

present before tungsten electrode

touches workpiece; only a low

sensing voltage is present between

electrode and workpiece. The

solid-state output contactor does

not energize until after electrode is

touching workpiece. This allows

electrode to touch workpiece with-

out overheating, sticking, or getting

contaminated.

1

1 − 2

Seconds

“Touch”

Do NOT Strike Like A Match!

2

Ref. S-156 279

5-5.

Stick Start Procedure

With Stick selected, start arc as fol-

lows:
1

Electrode

2

Workpiece

3

Arc

Drag electrode across workpiece

like striking a match; lift electrode

slightly after touching work. If arc

goes out electrode was lifted to high.

If electrode sticks to workpiece, use

a quick twist to free it.
Low OCV Stick
The unit can be optionally config-

ured for low open circuit voltage

(OCV) operation. When the unit is

configured for low OCV operation

only a low sensing voltage (approxi-

mately 15 VDC) is present between

the electrode and the workpiece

prior to the electrode touching the

workpiece. Consult a Factory

Authorized Service Agent for infor-

mation regarding how to configure

the unit for low OCV stick welding

operation.