Chapter 5 – AT Commands, S-Registers, and Result Codes

Multi-Tech Systems, Inc. SocketModem MT5600SMI Developer’s Guide

54

Command:

%U

Select µ-Law or A-Law Codec Type

Description:

Selects µ-Law or A-Law codec type for V.90 and 56K modulation.
This command also stores the selected setting directly to NVRAM.

Default:

Default value is country specific

Defined Values:

0

Selects µ-Law.

1 Selects

A-Law.

Result Codes:

OK
Otherwise ERROR

Command:

B

CCITT or Bell

Description:

When the modem is configured to allow either option, the modem will
select Bell or CCITT modulation for a line speed connection of 300 or 1200
bps. Any other line speed will use a CCITT modulation standard. The
parameter value, if valid, is written to S27 bit 6.

Default:

0

Defined Values:

B0

Selects CCITT operation at 300 or 1200 bps during Call
Establishment and a subsequent connection. (Default.)

B1

Selects BELL operation at 300 or 1200 bps during Call
Establishment and a subsequent connection.

Result Codes:

OK
Otherwise ERROR