+ES=6,,8

Enable V.80 Synchronous Access Mode.

+ES=3

Enable V.42 with Detection Phase originator. Disable V.80
Synchronous Access Mode originator.

+ES=,,2

Allow LAPM, MNP, or Normal Mode connection answerer.
Disable V.80 Synchronous Access Mode answerer.

+ES=3,,2

Enable V.42 with Detection Phase originator, allow LAPM,
MNP, or Normal Mode connection answer. Disable
Synchronous Access Mode originator and answerer.

Report Commands:

+ES?

Reports the current values
Response: +ES: <orig_rqst>,<orig_fbk>,<ans_fbk>
Example: +ES: 3,0,2 For the default setting.

+ES=?

Reports supported range of parameter values
Response: +ES: (<orig_rqst> range),( <orig_fbk> range),
(<ans_fbk> range)
Example: +ES: (0-4,6,7),(0-4),(0-6,8,9)

Command:

+EB

Break Handling in Error Control Operation

Description:

This extended-format compound parameter controls the break handling in
V.42 operation. It accepts three numeric subparameters:

Default:

None

Defined Values:

<break_selection>

Decimal number 0 specifying that break is to be
ignored, i.e., not signaled to remote DCE.

<timed>

Decimal number 0 specifying that any transmitted
V.42 L-SIGNAL will not indicate break signal length
<default_length> Decimal number 0 specifying that
break is not delivered to the DTE.

Report Commands:

+EB?

Reports current or selected values
Response: +EB:
<break_selection>,<timed>,<default_length><CR>
Example: +EB: 0,0,0 For default settings.

+EB=?

Reports supported range of parameter values
Response: +EB: (<break_selection> range),(<timed> range),

(default_length> range)

Example: +EB: (0),(0),(0)

Command:

+ESR

Selective Repeat

Description:

This extended-format numeric parameter controls the use of the selective
repeat (SREJ) option in V.42.
Decimal number 0 specifying that SREJ is not used.

Report Commands:

+ESR?

Reports Current or Selected Values:
Response: +ESR: <value>
Example: +ESR: 0 For default setting

+ESR=?

Reports Supported Range of Parameter Values
Response: +ESR: (<value>)
Example: +ESR: (0)

Command:

+EFCS

32-bit Frame Check Sequence

Description:

This extended-format numeric parameter controls the use of the 16-bit or
32-bit frame check sequence (FCS) option in V.42.

Defined Values:

<value> Decimal number 0 specifying the use of the 16-bit FCS specified

in V.42.

Report Commands:

+EFCS?

Current or Selected Values:
Response: +EFCS: <value>
Example: +EFCS: 0 For default setting.

+EFCS=?

Reporting Supported Range of Parameter Values
Response: +EFCS: (<value> range)
Example: +EFCS: (0)