4. connection diagram – Miller Electric Remote Operator Interface User Manual

Page 15

Advertising
background image

OM-217 834 Page 11

Ref. 803 697-E

Typical Swingarc installation shown;

however, various installations are

possible depending on the

application.
1

Remote Operator Interface

2

Swingarc Swivel Assembly

3

Boom

4

AA40G Wire Drive Assembly

5

Trigger Cable

4-3. Remote Operator Interface And Wire Drive Installation

1

2

3

4

5

5

803 698-E

1

Welding Power Source

2

Wire Feeder

3

Gas Cylinder

4

Gas Hose

5

Network Feeder Cable

6

Negative (−) Weld Cable

7

Workpiece

8

Voltage Sensing Lead

(Optional)

.

Positive (+) voltage sensing
lead is contained in the motor

cable.

9

Positive (+) Weld Cable

10 Motor Cable
11 Trigger Cable

4-4. Connection Diagram

1

2

3

4

5

7

8

9

6

10

11

11