Weld motr com pls wait, Over crnt low wfs, Estop – Miller Electric Remote Operator Interface User Manual

Page 30: Rmd done over aver, Rel trig err unkn, Wait, 2 . diagnostics (continued)

Advertising
background image

OM-217 834 Page 26

7-2.

Diagnostics (Continued)

WELD WAIT

•

The weld wait error indicates unit was not

ready for a weld sequence. Press Jog/

Purge button to clear error.

MOTR COM

•

The motor communication error indi-

cates motor board lost data communica-

tions. Press Jog/Purge button to clear error.

PLS WAIT

•

The uim communication error indicates

user interface board lost data

communications. Press Jog/Purge button

to clear error.

OVER CRNT

•

The over current error indicates welding

power source primary current is too high.

Check and correct input power. Press Jog/

Purge button to clear error.

LOW WFS

•

The low wire feed speed error indicates

actual wire feed speed is lower than wire

feed speed command. Check for

obstructions in the wire feed system or a

faulty wire drive system. Press Jog/Purge

button to clear error.

E STOP

•

The emergency stop error occurs if the

user presses an emergency stop button.

Reset the emergency stop button and press

Jog/Purge button to clear error.

RMD DONE

•

The RMD done error indicates the RMD

demo is completed. Press Jog/Purge button

to clear error.

OVER AVER

•

The over average error indicates that cur-

rent is outside the average range for the set

program parameters. Check and correct

program parameters. Press Jog/Purge but-

ton to clear error.

REL TRIG

•

The release trigger error indicates the

user held the trigger when starting a weld

program Press Jog/Purge button to clear

error.

ERR UNKN

•

The unknown error indicates a malfunc-

tion in the system somewhere. Press Jog/

Purge button to clear error.

WELD

MOTR

COM

PLS

WAIT

Indicates a weld

cycle wait error.

Indicates a motor

communication error.

Indicates a UIM

communication error.

OVER

CRNT

LOW

WFS

Indicates an

overcurrent error.

Indicates a low WFS

command error.

E

STOP

Indicates an

emergency stop error.

RMD

DONE

OVER

AVER

Indicates an arc

error.

Indicates an over

average current error.

REL

TRIG

ERR

UNKN

Indicates a trigger

closed error.

Indicates an

unknown error.

WAIT