OM-217 834 Page 19

5-7. Feeder Set Up Push Button

1

Feeder Set Up Push Button LED

2

Feeder Set Up Push Button

Press button to choose Sequence. Feeder

Set Up push-button LED will illuminate.

3

Sequence LED

When the Feeder Set Up button is pressed

once, the Sequence LED will illuminate and

the upper display will show sequence

options. Use the Adjust knob to select PRE

(preflow), STRT (start), CRTR (crater), or

POST (postflow).

Press the lower display push button and the

Lower Display push-button LED will

illuminate as well as the lower display. The

Time LED will automatically begin flashing

indicating that a time value can be entered

by turning the Adjust knob. By entering a

time value the sequence state will become

active. To turn off a sequence state, change

the time value to OFF. To step back for

selecting another sequence option, press

the Upper Display push button.

The Sequence option STRT and CRTR will

have additional parameter settings. By

pushing the Lower Display push button a

second time, while STRT or CRTR appear

in the upper display, allows entering voltage

(MIG) or Arc Adjust [Pulse, Accu-pulse, or

RMD (optional)]. Use the Adjust knob to

change the values indicated by the flashing

LED for either Volts or Arc Adjust. Pressing

the Lower Display push button a third time

will activate the WFS setting for either STRT

or CRTR and the WFS LED will begin flash-

ing. Use the Adjust knob to change the WFS

value.

Pressing the Feeder Set Up button two

more times will exit the Sequence menu and

return the system to standby mode.

4

Trigger Control LED

Press the Feeder Set Up button twice and

the Trigger Control LED will illuminate, and

the upper display will show the different trig-

ger control selections. Use the Adjust knob

to cycle through the trigger control methods

as follows: DS, TH, TDS, TPS, and 4T (see

Section 5-1 for definitions). The lower dis-

play will show the current state of each trig-

ger control method as being on or off. Not all

trigger control methods are compatible with

each other, therefore, turning on certain trig-

ger selections will cause other trigger selec-

tions to turn off.

Press the lower display push button to illu-

minate the push-button LED and enable the

use of the Adjust knob to allow turning se-

lected trigger control methods on or off. If

trigger hold is set to on, the Trigger Hold

LED will illuminate.

.

Trigger Hold is automatically set to On
with the 4T trigger selection. This is part

of the 4T function.

Press the Feeder Set Up button a third time

to cycle back to standby mode.

1

3

4

Trigger Control

Feeder Set Up

Trigger Hold

Sequence

Sequence Diagram

Preflow

Time

Start

Time

Crater

Time

Postflow

Time

2

5-8. Adjust Knob

Adjust

1

1

Adjust Knob

The Adjust knob is used to change

functions and parameters. Refer to

the front panel sections for

information regarding use of this

control.