Section 6 − setting sequence parameters, 1. sequence parameters in a program – Miller Electric Remote Operator Interface User Manual

Page 27

Advertising
background image

OM-217 834 Page 23

SECTION 6 − SETTING SEQUENCE PARAMETERS

6-1. Sequence Parameters In A Program

.

For more information on
Sequence mode, see Feeder

Set Up Push Button in Section

5-7.

Weld Time can only be set by using

an optional PDA with File

Management/WaveWriter software.
If time is set to zero in any timed

sequence, the sequence is skipped.

.

Maximum IPM may actually be
lower depending on the process

and wire type selection.

Trigger

Pressed

Trigger

Released

Start

Time

Preflow

Weld

Crater

Time

Postflow

Start

Time

Time

Postflow

Crater

Weld

Preflow

Sequence

End

Volts/Arc

Adjust

IPM

Seconds

2. Postflow

Off-5.0

1. Preflow

Off-5.0

Sequence

Parameters

3. Start

4. Crater

Off-5.0

Off-5.0

10.0-44.0/

0-99

40-1400

10.0-44.0/

0-99

40-1400