Error mode, On screen message – Marantz VP-11S1 User Manual

Page 40

Advertising
background image

32

ENGLISH

WARNING/LAMP indicator, ON indicator, and STANDBY indicator diagnose error mode of the projector as follows.

The lamp cover is not
closed properly.

The lamp has failed, or
the lamp is completely
worn out.

Projector internal
temperature is higher
than the allowed level.

Trouble has occurred
with the fan.

Internal program error

Close the cover correctly.

Replace the lamp and
reset lamp life.

Check if anything is
blocking the exhaust vent.

Shut power OFF and
ON again.

Other

Fan

Temperature

Lamp

Lamp cover

Flashing

Flashing

Flashing

ON

ON

OFF

OFF

OFF

OFF

OFF

Flashing

ON

OFF

Flashing

OFF

Indicators

Error mode

WARNING

/LAMP

ON

STANDBY

Possible Cause

Recommendation

ERROR MODE

NO SIGNAL

REPLACE LAMP!

OUT OF RANGE

No input signal.

The lamp has reached the end of its life.

Improper signal feed to the projector.

Properly connect the cables.

Replace the lamp and reset lamp life.

Adjust resolution, V(Hz) : refresh rate of the
equipment, referring to the Timing Chart.

Meaning

Message

Remedy

Use the list below to check the message displayed on the screen.