Motorola F5217A User Manual
Page 10
 
10 MW800 Owner’s Manual
 
If the system does not respond, you can turn the device off by pressing and holding 
the display power button for 6 seconds or more. To permit this option, Critical turn 
off parameter (see Section 3) setting should be ENABLE. Be aware, this hardware 
power off may damage your hard disk. 
 
Extreme Shut Down
Some extreme events might cause the device to power off. These are ambient 
temperature below the low or above the high operating limit or discharged car 
battery. 
 
• Internal temperature is beyond the operational limit.
If during operation the internal temperature goes out of the low operational 
limits, the display eventually powers off. 
 
• Vehicle battery is discharged. 
If, during normal operation, the battery voltage drops below 10.5VDC the 
display will provide Low Battery indication (the power indicator blinks 
yellow). If the voltage continues to drop, the device automatically powers off 
at 8.5VDC. 
 
• Drops in car battery voltage.
If battery voltage drops below the 8.8V limit for 20 seconds or more, the 
device will execute critical shut off and power itself off. 
Power Management
This chapter describes how to enter the CPU into low-power mode (standby) and 
resume normal operating mode. 
Standby
The display can enter the CPU into low-power state by pressing the Standby button 
on the right display’s side. 
 
One more way to move the CPU into low-power mode is to configure the Power 
button to enter the CPU into a low-power state. For details about this option, refer to 
the help file attached to Power Options (Start -> Settings -> Control Panel -> 
Power Options). 
Resume
The display can resume the CPU using the following methods: 
 
• A contact to the touch panel of the MW800 display