2. xr-water-cooled gun connections – Miller Electric OM-227 398D User Manual

Page 11

Advertising
background image

OM-227 398 Page 7

4-2. XR-Water-Cooled Gun Connections

Ref. 801 577-A / 805 106-A

.

Turn on coolant supply before
welding or gun will be dam-

aged.

1

Gun Control Cable

Insert plug into Gun Control

receptacle, and tighten threaded

collar.
2

Gun Connector

3

Gun Securing Knob

4

Gun Connector Block

Loosen gun securing knob, and

insert gun connector through Wire

opening until it bottoms against

block. Tighten knob. Close and

latch door.
5

Gun (Coolant) “In” Hose

Connect to Water “In” fitting on

feeder (left-hand threads).
6

Gun (Coolant) “Out” Hose

Connect to Water “Out” fitting on

feeder (left-hand threads)
7

Water (Coolant) Output

8

Water (Coolant) Input

9

XR Control (Coolant) Output

10 XR Control (Coolant) Input
Close and latch door.

Tools Needed:

1

5

6

9/16 in

4

3

2

Left Side

7

8

9

10

Advertising