OM-227 398 Page 8

4-3. Millermatic 350P Water Cooled Gun Connections

Ref. 804 945-A

.

Turn on coolant supply before welding
or gun will be damaged.

1

Coolant Supply

2

Millermatic 350P

3

Gun Control Cable

Insert plug into gun control receptacle and

tighten threaded collar.

4

Water In Hose

Connect to coolant supply with supplied

coupler and water hose (left-hand threads).

5

Gun Connector

Loosen gun securing knob, and insert gun

connector through Wire opening until it

bottoms against block. Tighten knob. Close

and latch door.
6

Water Out Hose

Connect to coolant supply with supplied

coupler and water hose (left-hand threads).
7

Coolant “In”

8

Coolant “Out”

Tools Needed:

5

9/16 in

6

4

3

1

2

8

7