SECTION 2

INSTALLATION

OM-179 078

2-8

2.6

REMOTE CONTROLS

A number of remote capabilities are available with the DWF–3 system. On the rear panel of the control unit a
connector is provided for remote operation. The remote connector, in addition to providing for the remote
control connections, provides the user access to other wire feeder signals. This may be used to incorporate
the DWF–3 into a complete welding package system. The signals available are listed in Figure 3.3 and are
described in more detail in Section 3.4. The factory also provides an optional prewired connector and shielded
cable for connection to these signals. (See Sections 3.4).

2.7

CHANGING RETRACT DISTANCE

The wire retract distance which occurs at the end of a wire feed cycle comes preset from the factory at 0.512
inches. This distance can be changed thru the range of 0.085 inches to 1.28 inches by changing the ”E”
jumpers. (See Table 4.3).