SECTION 4
MAINTENANCE AND REPAIR
OM-179 078
4-6
The standard setting for the DWF–3 is 0.512 in. However, the following lengths may be obtained by inserting
jumpers from P1, P2, P3, and P4 on the U12 IC Circuit to +12V and ground as shown:
TABLE 4.3 AVAILABLE RETRACT LENGTHS
LENGTH DESIRED
JUMPER CONNECTION TO +12 V AND GROUND FROM:
INCHES
MM
P1
P2
P3
P4
0.085
2.15
+12
GND
GND
GND
0.170
4.32
GND
+12
GND
GND
0.256
6.50
+12
+12
GND
GND
0.341
8.67
GND
GND
+12
GND
0.427
10.86
+12
GND
+12
GND
0.512*
13.00
GND
+12
+12
GND
0.597
15.16
+12
+12
+12
GND
0.683
17.35
GND
GND
GND
+12
0.768
19.51
+12
GND
GND
+12
0.853
21.67
GND
+12
GND
+12
0.939
23.85
+12
+12
GND
+12
1.024
26.00
GND
GND
+12
+12
1.109
28.17
+12
GND
+12
+12
1.195
30.35
GND
+12
+12
+12
1.280
32.51
+12
+12
+12
+12
*Standard