SECTION 4

MAINTENANCE AND REPAIR

OM-179 078

4-6

The standard setting for the DWF–3 is 0.512 in. However, the following lengths may be obtained by inserting
jumpers from P1, P2, P3, and P4 on the U12 IC Circuit to +12V and ground as shown:

TABLE 4.3 AVAILABLE RETRACT LENGTHS

LENGTH DESIRED

JUMPER CONNECTION TO +12 V AND GROUND FROM:

INCHES

MM

P1

P2

P3

P4

0.085

2.15

+12

GND

GND

GND

0.170

4.32

GND

+12

GND

GND

0.256

6.50

+12

+12

GND

GND

0.341

8.67

GND

GND

+12

GND

0.427

10.86

+12

GND

+12

GND

0.512*

13.00

GND

+12

+12

GND

0.597

15.16

+12

+12

+12

GND

0.683

17.35

GND

GND

GND

+12

0.768

19.51

+12

GND

GND

+12

0.853

21.67

GND

+12

GND

+12

0.939

23.85

+12

+12

GND

+12

1.024

26.00

GND

GND

+12

+12

1.109

28.17

+12

GND

+12

+12

1.195

30.35

GND

+12

+12

+12

1.280

32.51

+12

+12

+12

+12

*Standard