MultiModemDSVD User Guide

4 AT Commands, S-Registers, and Result Codes

34

Multi-Tech Systems, Inc.

Command:

&C

n

Data Carrier Detect (DCD) Control

Values:

n = 0 or 1

Default:

1

Description:

&C0 Forces the DCD circuit to always be high.
&C1 DCD goes high when the remote modem’s carrier signal is de-

tected, and goes low when the carrier signal is not detected.

Command:

&D

n

Data Terminal Ready (DTR) Control

Values:

n = 0, 1, 2, or 3

Default:

2

Description:

This command interprets the high to low transition of the DTR
signal from the computer according to the supplied parameter.
The action taken depends on the current &Q setting.

&D0 &Q0, &Q5, &Q6: DTR is ignored (assumed high). Allows op-

eration with computers that do not provide DTR.

&D1 &Q0, &Q5, &Q6: DTR drop is interpreted by the modem as if

the asynchronous escape sequence had been entered. The mo-
dem returns to asynchronous command state without discon-
necting.

&D2 &Q0&Q6: DTR drop causes the modem to hang up. Autoan-

swer is inhibited.

&D3 &Q0, &Q5, &Q6: DTR drop causes the modem to perform a

soft reset as if the Z command were received. The &Y setting de-
termines which profile is loaded.
&Q5

or &Q6 and +FCLASS=1 or +FCLASS=2: Same as for &Q0.

Note:

If &D1, &D2, or &D3 is set, the modem will not dial

without a DTR drop.

Command:

&E

n

V.42 Error Correction Modes

Values:

n = 0, 1, or 2

Default:

1

Description:

&E0

V.42 non-error correction mode (V.42 disabled).

&E1

V.42 auto-reliable mode.

&E2

V.42 reliable mode (V.42 enabled).

Command:

&E

n

Modem-Initiated Flow Control

Values:

n = 3, 4, or 5

Default:

4

Description:

&E3

Flow control disabled.

&E4

CTS/RTS hardware flow control.

&E5

XON/XOFF software flow control.

Note:

See also the L5 and &K commands.