4-10. Remote 14 Receptacle Information

Socket*

Socket Information

24 VOLTS AC

A

24 volts ac. Protected by circuit breaker CB2.

B

Contact closure to A completes 24 volts ac contactor control circuit.

115 VOLTS AC

I

115 volts ac. Protected by circuit breaker CB1.

J

Contact closure to I completes 115 volts ac contactor control circuit.

C

Output to remote control; +10 volts dc in MIG mode.

REMOTE

OUTPUT

D

Remote control circuit common.

OUTPUT

CONTROL

E

0 to +10 volts dc input command signal from remote control.

M

Remote mode select

A/V

AMPERAGE

F

Current feedback; +1 volt dc per 100 amperes.

AMPERAGE

VOLTAGE

H

Voltage feedback; +1 volt dc per 10 arc volts.

GND

G

Circuit common for 24 and 115 volts ac circuits.

GND

K

Chassis common.

*The remaining sockets are not used.

4-11. Connecting Remote Control

Ref. 800 166-D / Ref. S-0004-A / S-0750

!

Turn off power before con-

necting to Remote 14 recep-

tacle.

1

Remote 14 Receptacle RC14

Connect remote control to RC14.

A

J

B

K

I

C L N

H

D M

G

E

F