7. selecting weld cable sizes, 8. remote 14 receptacle rc14 information – Miller Electric PipePro 304 User Manual

Page 25

Advertising
background image

OM-492 Page 21

5-7. Selecting Weld Cable Sizes*

Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit

Not Exceeding***

100 ft (30 m) or Less

150 ft

(45 m)

200 ft

(60 m)

250 ft

(70 m)

300 ft

(90 m)

350 ft

(105 m)

400 ft

(120 m)

Weld Output

Welding

Amperes

10 − 60%

Duty

Cycle

60 − 100%

Duty

Cycle

10 − 100% Duty Cycle

Weld Output

Terminals

100

4 (20)

4 (20)

4 (20)

3 (30)

2 (35)

1 (50)

1/0 (60)

1/0 (60)

!

Turn off power before

connecting to weld

150

3 (30)

3 (30)

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

3/0 (95)

connecting to weld

output terminals.

200

3 (30)

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120) 4/0 (120)

!

Do not use worn,

damaged, under-

sized, or poorly

250

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120) 2 ea. 2/0

(2x70)

2 ea. 2/0

(2x70)

sized, or poorly

spliced cables.

300

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120) 2 ea. 2/0

(2x70)

2 ea. 3/0

(2x95)

2 ea. 3/0

(2x95)

350

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120) 2 ea. 2/0

(2x70)

2 ea. 3/0

(2x95)

2 ea. 3/0

(2x95)

2 ea. 4/0

(2x120)

*

This chart is a general guideline and may not suit all applications. If cable(s) overheat, use next size larger cable.

**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.

( ) = mm

2

for metric use

S-0007-F

***For distances longer than those shown in this guide, call a factory applications representative at 920-735-4505.

5-8. Remote 14 Receptacle RC14 Information

.

Engine runs at weld/power speed whenever a device connected to the remote 14 receptacle is running.

Socket*

Socket Information

24 VOLTS AC

A

24 volts ac. Protected by supplementary protector

CB6.

B

Contact closure to A completes 24 volts ac

contactor control circuit.

A

J

B

K

I

L N

H

115 VOLTS AC

I

115 volts ac. Protected by supplementary protec-

tor CB5.

C L N

H

D M

G

E

F

J

Contact closure to I completes 115 volts ac

contactor control circuit.

E

F

C

Output to remote control; 0 to +10 volts dc, +10

volts dc in MIG mode.

REMOTE

OUTPUT

D

Remote control circuit common.

OUTPUT

CONTROL

E

0 to +10 volts dc input command signal from

remote control.

M

CC/CV select.

A/V

F

Current feedback; +1 volt dc per 100 amperes.

A/V

AMPERAGE

VOLTAGE

H

Voltage feedback; +1 volt dc per 10 output recep-

tacle volts.

802 174-G

GND

G

Circuit common for 24 and 115 volts ac circuits.

GND

K

Chassis common.

*The remaining sockets are not used.

Advertising