8-10.Voltmeter/Ammeter Help Displays

Use the voltmeter/ammeter help displays to

help determine the cause of no weld output.

When a help display is shown, the inverter

module weld output has stopped but the en-

gine continues to run. Correct the problem

before resuming operation.

The display screen resets when the fault is

corrected.

.

All directions are in reference to the front
of the unit. All circuitry referred to is lo-

cated inside the inverter module.

1

Help 0 Display

Indicates a shorted thermistor RT2 on the left

side of the unit. If this display is shown, con-

tact a Factory Authorized Service Agent.

2

Help 1 Display

Indicates a malfunction in the primary power

circuit possibly caused by applying a high

weld load at idle speed. Turn Engine Control

switch to Run position. If problem continues,

contact a Factory Authorized Service Agent.

3

Help 2 Display

Indicates a malfunction in the thermal protec-

tion circuitry located on the left side of the unit.

If this display is shown, contact a Factory Au-

thorized Service Agent.

4

Help 3 Display

Indicates the left side of the unit has over-

heated. The unit has shut down to allow the

fan to cool it (see Section 4-3). Operation will

continue when the unit has cooled.

5

Help 4 Display

Indicates a malfunction in the thermal protec-

tion circuitry located on the right side of the

unit. If this display is shown, contact a Factory

Authorized Service Agent.

6

Help 5 Display

Indicates the right side of the unit has over-

heated. The unit has shut down to allow the

fan to cool it (see Section 4-3). Operation will

continue when the unit has cooled.

7

Help 6 Display

Indicates that the input voltage is too low and

the unit has automatically shut down. Opera-

tion will continue when the voltage is within the

acceptable lower range limit (15% below the

applicable input voltage). If this display is

shown, have a Factory Authorized Service

Agent check the power generator output volt-

age.
8

Help 7 Display

Indicates that the input voltage is too high and

the unit has automatically shut down. Opera-

tion will continue when the voltage is within the

acceptable upper range limit (15% above the

applicable input voltage). If this display is

shown, have a Factory Authorized Service

Agent check the power generator output volt-

age.
9

Help 8 Display

Indicates a malfunction in the secondary pow-

er circuit of the unit. If this display is shown,

contact a Factory Authorized Service Agent.
10 Help 9 Display
Indicates a shorted thermistor RT1 on the

right side of the unit. If this display is shown,

contact a Factory Authorized Service Agent.