PAGE 18 — DCA85USJ2 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #1 (03/22/11)

DIAGNOSTIC DISPLAY

Figure 4. Diagnostic Display

The diagnostic display panel located inside the control box
on the generator (Figure 4) is designed to meet the needs
for instrumentation and control of electronically controlled
engine communication using the SAEJ1939 Controller Area
Network (CAN). This diagnostic display is a multifunction
tool that enables equipment operators to view many
different engine parameters and service codes.

The keypad on the diagnostic display panel is a capacitive
touch sensing system. There are no mechanical switches
to wear or stick. This keypad (display unit) will operate in
extreme hot or cold weather conditions.

Other components in the system are microprocessor-based
components for displaying critical engine data broadcast
by an electronic engine or transmission’s Engine Control
Unit (ECU): engine RPM, oil pressure, coolant temperature,
system voltage, etc., and a combination audible alarm and
relay unit for warning and shutdown annunciation.

The Engine Control Unit (ECU) used with this generator
diagnosis engine faults that arise with the the engine
control system and the engine itself. Engine faults can
be determined by viewing the Diagnostic Trouble Codes
(Active Fault Codes) which are displayed on the Diagnostic
Display Panel. See the John Deere Engine Operator’s
Manual for a complete listing of active fault codes and
countermeasures.

The following defi nitions describe the controls and functions
of the Diagnostic Display Panel (Figure 4).

1. Menu Button – Press this button to enter or exit menu

screens.

2. Left Arrow Button – Press this button to scroll through

the screen either moving the parameter selection
toward the left or upward.

3. Right Arrow Button – Press this button to scroll

through the screen either moving the parameter
selection toward the right or downward.

4. Enter Key Button – Press this button to select the

parameter that is highlighted on the screen.

5. Emergency Stop LED – When lit (RED) indicates a

major fault has occured. This condition will shudown
the generator.

6. Warning LED – When lit (AMBER), indicates a engine

parameter has exceeded its limits (minor fault). The
generator will still run in this condition.

7. Display Screen – Graphical backlight LCD screen.

Back lighting is controlled via menu or external
dimmer potentiometer. The display can show either a
single parameter or a quadrant display showing four
parameters simultaneously.

8. Diagnostic Switch – When placed in the ON position,

will activate the diagnostic display panel.

9. CAN Diagnostic Connector – Controller Area

Network connector. This connector outputs diagnostic
error codes. Connect a scanner or similar device into
this connector to read error codes.

Display Parameters

The following are some of the engine and transmission
parameters displayed on the diagnostic disply panel.

 Engine RPM’s

 Engine Hours

 System Voltage

 % Engine Load at current RPM

 Coolant Temperature

 Oil Pressure

 Fuel Economy

 Current Fuel Consumption

 Throttle Position

 Engine Manifold Air Temperature

 Active Service Codes

 Set Units for Display (English or Metric)

 English Confi guration Parameters.