4.7

CDM-700 Modem Connections

If adding a modem to an operating 1:N system, care needs to be taken to not interfere with the
existing traffic. The cabling, power-up sequence and communication connections must be correct
to avoid contention in the system from the modem Tx carrier. This information is detailed in

Chapter 7.4.5 - (CONFIG) ACTIVE MODEMS

.

4.7.1

RMI/TMI Limitations and Considerations

IM PORTAN T

1. Traffic modems with differing data types can all be supported by the

Redundant Modem.

2. Depending on the traffic data type, the appropriate jumper settings are

provided on the TMI to ensure proper operation for HSSI with CA/TA signals
using the CRS-336 TMI. Refer to
Chapter 4. MODEM, TMI, AND SWITCH
CONFIGURATION for this important configuration information.

4.7.2

Interface Combinations

With (2) interface card slots available in the CDM-700 modem, there are many possible interface card
combinations. The CRS-300 can cover many of these combinations, but not all. Table 4-2 provides
details for the CDM-700 interface card combinations that are compatible with the CRS-300.

Table 4-2. CDM-700 Interface Card Combinations

CDM-700 Modem Configuration

1:N CRS-300 Configuration

Notes

Interface Slot 1

Interface Slot 2

TMI Card

RMI Card

G.703 (CDI-10)

None CRS-345

CRS-306

-

G.703 (CDI-10)

CRS-345

CRS-306

-

HSSI (CDI-60)

Not Supported

Not Supported

Exceeds backplane capability

GbE (CDI-70)

CRS-345

CRS-306

Use wired-around GigE

(see Chapter 3)

OC3 Copper
(CDI-50)

None

CRS-325 CRS-306

-

GbE (CDI-70)

Valid for Redundant modem

HSSI (CDI-60)

None CRS-336

CRS-306

-

HSSI (CDI-60)

None

None

Exceeds backplane capability

GbE (CDI-70)

CRS-336

CRS-306

Use wired-around GigE

(see Chapter 3)

GbE (CDI-70)

None

CRS-336 CRS-306

-

GbE (CDI-70)

Use wired-around GigE

(see Chapter 3)

None

G.703 (CDI-10)

CRS-345

CRS-306

-

HSSI (CDI-60)

CRS-336

-

GbE (CDI-70)

-

Notes:

1. The Redundant CDM-700 must have the same interface cards in each slot as any of the

Traffic CDM-700s.