CRS-300 1:10 Redundancy Switch

Revision 16

Front Panel Operation

MN/CRS300.IOM

7–11

7.4.4 CONFIG: REMOTE

SELECT REMOTE CONTROL:
LOCAL REMOTE (PRESS ENT)

Select LOCAL or REMOTE using the ◄ ► arrow keys, then press

[ENT]

.

CONFIG: REMOTE

Æ LOCAL

If LOCAL is selected, remote control will be disabled, though remote monitoring is always
possible.

CONFIG: REMOTE

Æ REMOTE

If REMOTE is selected:

REMOTE CONTROL: BAUDRATE
INTERFACE (PRESS ENTER)

Select BAUDRATE or INTERFACE, using the ◄ ► arrow keys, then press

[ENT]

.

CONFIG: REMOTE

Æ REMOTE Æ BAUDRATE

If BAUDRATE is selected:

EDIT SWITCH BAUDRATE:
19200 BAUD (PRESS ENT)

The User may select the baud rate of the remote control bus, connected locally to the M&C
computer. Change the value by using the ▲ ▼ arrow keys. Values of 300, 1200, 2400, 4800,
9600 and 19200 baud are possible.

Once baudrate has been set, the User should pres ENT.

Note: This setting does not affect the internal communications between the Switch and the modems.

CONFIG: REMOTE

Æ REMOTE Æ INTERFACE

If INTERFACE is selected:

ELECT. INTERFACE: RS232
RS485-2W RS485-4W (ENT)

Select RS232, RS485-2W (2-wire), or RS485-4W (4-wire) using the ◄ ► arrow keys, then press

[ENT]

. The User will be further prompted to enter the bus address.

In this example, RS-232 mode is used and the bus address is fixed at 0:

IN RS232 MODE THE BUS
ADDRESS IS FIXED AT 0000

If in RS-485, the address may be selected. The valid addresses are 1000, 3000, 5000 and 7000
only, as explained in

Appendix C. REMOTE CONTROL

in this manual.