background image

CRS-300 1:10 Redundancy Switch

Revision 16

Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM

5–14

Table 5-5

illustrates the control signal configuration JP1 and JP2 jumper settings available on the

CRS-320 (obsolete) and CRS-340 TMIs:

Table 5-5. CRS-320/CRS-340 Jumper Settings

Jumper ‘JP1’


Jumper ‘JP2’

Control Signal Setting

Jumpers

Settings

Control Signal Setting

Jumpers

Settings

RTS/CTS

Open Circuit

(TMI as-shipped)

None

DTR/DSR

Open Circuit

(TMI as-shipped)

None

RTS to CTS Loop

1 to 3
2 to 4

DTR to DSR Loop

1 to 3
2 to 4

TX IF

“User Mute Control”

Connects User DB-25 Pin
23 to Online Modem’s
“Tx_IF_Mute_L”:
0 = Mute = Tx_IF Off
1 = No Mute = Tx_IF On

3 to 5

Note: These jumper settings are available only on the following TMI versions: