OM-2229 Page 21

6-2. Overload Protection: Trouble Lights & Checking Shield Cup Shutdown System

1

Power Light

Light is steady if input power is

okay. Light flashes for the following

conditions:

a

If input power is 115 volts

ac, but power supply is

less than 92 volts ac or

greater than 138 volts ac.

b

If input power is 230 volts

ac, but power supply is

less than 194 volts ac or

greater than 276 volts ac.

If certain problems occur a trouble

light comes on, and output stops.
2

Pressure Light

Lights if gas/air pressure is below

40 PSI (276 kPa).
Turn power Off, and check for

proper gas/air pressure (see

Section 5-1).
A flashing Pressure light indicates

that gas/air system may be set too

low, faulty, leaking or has a flow re-

striction (see Section 6-5).
3

Cup Light

Lights if shield cup is loose.
Turn power Off, and check shield

cup connection (see torch Owner’s

Manual). Power must be reset

whenever the cup shutdown is

activated.
A flashing Cup light indicates that

the torch consumables are stuck or

worn and should be inspected and/

or replaced (see Section 6-4).
Check shield cup shutdown system

once a week.
4

Temperature Light

Lights if power source overheats or

when ambient temperature is below

−35

°

C (−31

°

F) (see Section 4-3).

5

Torch Shield Cup

Turn Power On and loosen shield

cup. If shutdown system works

properly, Ready light goes off and

Cup light comes on. If not, turn

power Off and check for proper

gas/air pressure (see Section 4-1),

blocked or leaking hose, or loose

shield cup (see torch Owner’s

Manual).
If system works properly, retighten

cup and reset power.

Ref. 200 808 / Ref. 802 877

Checking Torch Shield Cup Shutdown System

Power must be reset whenever the cup shutdown system is activated.

Always turn Off power when changing or checking consumables.