4-9. Selecting Cable Sizes

To reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor.

Locate welding operation 100 meters from any sensitive electronic equipment. Be sure this welding machine is installed

and grounded according to this manual. If interference still occurs, the user must take extra measures such as moving

the welding machine, using shielded cables, using line filters, or shielding the work area.

NOTICE ARC WELDING can cause Electromagnetic Interference.

Total Cable (Copper) Length In Weld Circuit Not Exceeding

100 ft (30 m) Or Less

150 ft

(45 m)

200 ft

(60 m)

250 ft

(70 m)

300 ft

(90 m)

350 ft

(105 m)

400 ft

(120 m)

Welding

Amperes

10 − 60%

Duty

Cycle

60 − 100%

Duty Cycle

10 − 100% Duty Cycle

100

4

4

4

3

2

1

1/0

1/0

150

3

3

2

1

1/0

2/0

3/0

3/0

200

3

2

1

1/0

2/0

3/0

4/0

4/0

250

2

1

1/0

2/0

3/0

4/0

2-2/0

2-2/0

300

1

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

350

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

2-4/0

400

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-4/0

2-4/0

500

2/0

3/0

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-3/0

600

3/0

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-4/0

3-4/0

700

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-4/0

3-4/0

4-4/0

800

4/0

2-2/0

2-3/0

2-4/0

3-4/0

3-4/0

4-4/0

4-4/0

*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. Contact your

distributor for the mm

2

equivalent weld cable sizes.

S-0007-E

4-10. Connecting Weld Output Cables

803 778-B

!

Turn off power before connecting to

weld output terminals.

!

Failure to properly connect weld

cables may cause excessive heat

and start a fire, or damage your ma-

chine.

1

Weld Output Terminal

2

Supplied Weld Output Terminal Nut

3

Weld Cable Terminal

4

Copper Bar

Remove supplied nut from weld output ter-

minal. Slide weld cable terminal onto weld

output terminal and secure with nut so that

weld cable terminal is tight against copper

bar. Do not place anything between weld

cable terminal and copper bar. Make

sure that the surfaces of the weld cable

terminal and copper bar are clean.