OM-278 Page 24

SECTION 6 − MAINTENANCE & TROUBLESHOOTING

6-1. Routine Maintenance

!

Disconnect power before maintaining.

3 Months

Replace

unreadable

labels.

Clean and

tighten weld

terminals.

Repair or

replace

cracked weld

cable.

6 Months

Blow out or vacuum inside.

During heavy service, clean monthly.

OR

6-2. Fuse F1

Ref. 800 101-C

!

Disconnect and lockout/tag-

out input power before

checking or changing fuse.

1

Fuse F1 (See Parts List For

Rating)

Fuse F1 protects control transform-

er from overload. If F1 opens, weld

output and fan motor stops. Re-

place F1.
Close and secure access door.

1

Tools Needed:

3/8 in

6-3. Short Circuit Shutdown

When contact tip is shorted and sticks to workpiece, the unit output falls to a safe operating level. To resume operation,

release gun trigger, turn Off unit, and remove contact tip from workpiece. Check contact tip and replace if damaged.

Turn On unit to continue operation.