Caution – Maytag MGC5536 User Manual

Page 9

Advertising
background image

9

B. INVERT CAP IN APPLIANCE PRESSURE

REGULATOR (See figure 11)

With the appliance installed, the appliance regulator
should be located as shown in figure 3, 4 or 5.

FIGURE 11

CONVERSION OF APPLIANCE

PRESSURE REGULATOR

C. LOW FLAME ADJUSTMENT

(See figure 12)

This appliance is shipped from the factory with low and
high flame settings adjusted for use with natural gas.
To set for use with LP proceed as follows:

1. Remove control knob from valve stem.

CAUTION:

NEVER USE A METAL BLADE TO

PRY KNOB OFF. IF KNOB CANNOT BE EASILY
REMOVED, TUCK THE FOLDS OF A CLOTH
DISHTOWEL UNDER THE KNOB AND PULL THE
TOWEL UPWARD WITH STEADY, EVEN PRES-
SURE.

2. Carefully remove rubber grommet.

3. Locate the valve adjustment screw. See figure 12.

4. Insert a slender, thin-blade screwdriver into knob

hole and engage blade with slot in adjusting screw.

5. Turn the adjusting screw clockwise until tight (5-7

in-lbs max.). Do not over tighten.

6. Replace rubber grommet and control knob.

7. Repeat for remaining burners.

FIGURE 12

KNOB

ADJUSTMENT

SCREW

KNOB HOLE

(KNOB AND GROMMET REMOVED)

After adjusting the screw the burner should produce a
stable, steady blue flame of minimum size. The setting
should be checked by turning knob from high to low
several times without extinguishing the flame.

This operation will automatically provide the proper flame
size at medium setting.

After Conversion Steps A, B and C have been completed,
check the appearance of each burner flame at the Hi and
Lo settings against figure 13. If the flames appear too
large or too small, review each step to make sure it was
completed correctly.

FIGURE 13

FLAME APPEARANCE AT HI AND LO

Advertising
This manual is related to the following products: