Powerline MU Inductive Coupler

•

Useful in individually-metered and multiple
transformer buildings such as apartments and
condominiums which have one or more meter
banks with meters that monitor power
consumption to individual residences

•

Connect one coupler per phase just before the
meter bank in the Termination Cabinet over the
insulated portion of the electric cable

•

Provides efficiency in signal distribution by

injecting on the larger wires just before the meter bank and subsequent branching to
individual residences with no contact to the actual metal conductor

•

Three coupler sizes to accommodate various wiring gauges

500

Part Number

0171486N21

Part Name

Powerline MU Inductive Coupler 500

Description

Optional Powerline MU coupler to Induce Signal onto in-
building cables before the Meter Bank.

High Voltage Interface

Fits up to 500 MCM cable rated 380A

Cable

75 Ohm Coaxial

Connectors

F-Connector (Coaxial)

Center Conductor

600v rated 22-gauge stranded copper THHN wire

Dimensions

2.8 in x 2.3 in x 2.2 in (70.14 mm x 58.3 mm x 55mm)

Inner Diameter of core

1 in (25.4 mm)

Outer Diameter of Core

2.02 in (51.31 mm)

Weight

.90 lbs

Operating temperature

-40°C to 55°C (-40°F to 131°F)

Safety

UL authorization (In conjunction with Powerline MU Gateway)

250

Part Number

0171486N23

Part Name

Powerline MU Inductive Coupler 250

Description

Optional Powerline MU coupler to Induce Signal onto in-
building cables before the Meter Bank.

High Voltage Interface

Fits up to 250 MCM cable rated 255A

Cable

75 Ohm Coaxial

Connectors

F-Connector (Coaxial)

Center Conductor

600v rated 22-guage stranded copper THHN wire

Dimensions

2.8 in x 2.3 in x 2.2 in (70.14 mm x 58.3 mm x 55mm)

Inner Diameter of core

.76 in (19.4 mm)

Outer Diameter of Core

2.02 in (51.31 mm)

Weight

.99 lbs

Operating temperature

-40°C to 55°C (-40°F to 131°F)

Safety

UL authorization (In conjunction with Powerline MU Gateway)