INSTALLATION

7

Figure 5

Hot Water Connection

(MH-60 Only)

3/4" NPT

Figure 8

Hot Water Connection

(MH-6N, MH-6L Only)

3/4" NPT

INSTALLATION (Cont.)

Plumbing Connections

NOTE:

Plumbing connections must comply
with all applicable sanitary and
plumbing codes.

Water Connections

1. All MH series dishwashers require

a single, hot water supply.

The hot water connection to all MH
series dishwashers is 3/4" NPT.

The connection is made from
underneath the dishwasher.

The following minimum water
temperatures are recommended:

MH-60 with built-in 40° rise electric
booster (Minimum 140°F/60°C)
(Min./Max. flow pressure
20-22 PSI/138-151.8 kPa)

MH-60 with built-in 70° rise electric
booster (Minimum 110°F/43°C)
(Min./Max. flow pressure
20-22 PSI/138-151.8 kPa)

MH-6N without built-in booster
(Minimum 180°F/70°C)
(Min./Max. flow pressure
20-22 PSI/138-151.8 kPa)

MH-6L low temperature
(Minimum 120°F/49°C-
140°F/60°C Optimum)
(Min./Max. flow pressure
20-22 PSI/138-151.8 kPa)

Refer to Figs. 5 and 6

12"

[305mm]

FLOOR

12"

[305mm]

FLOOR