INSTALLATION (Cont.)

Chemical Connections

NOTE:

Consult a qualified chemical supplier
for your chemical needs.

Refer to Fig. 8

1. A chemical signal terminal block is

supplied for chemical dispensing
equipment.

2. The terminal block is located below

the control panel fuse block.

Refer to Fig. 9

3. The detergent signal is limited

to a maximum load of 1 Amp.
Signal voltage is 115VAC.

4. The Rinse aid/Sanitizer

signal is limited to a max-
imum load of 1 Amp.
Signal voltage is 115VAC.

Rinse aid/Sanitizer
Signal Connection Point
1 Amp Max load/115VAC

Figure 8

Chemical Dispenser

Signal

Terminal Block

Figure 9

Chemical Signal

Connection Points

Common Return

Detergent Signal Connection Point
1 Amp Max Load/115VAC