BASIC SERVICE

29

Electrical Service (Cont.)

Motor Connections —

1. Models MH-60, MH-6N, and MH-6L are available in either single phase or 3 phase voltages.

2. Motor rotation was set at the factory. For three phase machines, reversing the motor direction

is done in the control cabinet by reversing the wires L1 and L2 on the disconnect side of the
main electrical connection block. For single phase machines, motor rotation is changed at the
motor connection plate on the rear of the single phase motor (if necessary).

Refer to Fig. 20 for the proper wiring of the pump motor for single and three phase voltages.

SINGLE PHASE - LOW VOLTAGE

L1

L2

4

2

8

J

LINE

LINE

3

SINGLE PHASE - HIGH VOLTAGE

2

8

J

LINE

LINE

L1

L2

4

3

Figure 18

Pump Motor Wiring Diagrams

208-240V

THREE PHASE - LOW

VOLTAGE

480V

THREE PHASE - HIGH

VOLTAGE

575V ONLY

THREE PHASE

6

5

4

9

8

7

3

2

1

LINE

6

5

4

9

8

7

3

2

1

LINE

3

2

1

LINE