Pstn, 17 chapter 2 - installation, Voice/fax channel 1 - 8 connections – Multi-Tech Systems FR3060 User Manual

Page 17

Advertising
background image

17

Chapter 2 - Installation

Voice/Fax Cable Connections

NOTE: The E&M, FXS, and Ethernet ports are not designed to be connected to a Public
Telecommunication Network.

6

If you are connecting a station device; e.g., analog telephone, fax machine, or Key Telephone
System (KTS) to your MultiFRAD; connect one end of an RJ-11 phone cord to the Voice/Fax
Channel 1 FXS
connector on the back of the MultiFRAD and the other end to the station
device. See Figure 5.

E&M

FXO

FXS

E&M

FXO

FXS

E&M

FXO

FXS

E&M

FXO

FXS

VOICE/

FAX

CHANNEL

8

VOICE/

FAX

CHANNEL

4

VOICE/

FAX

CHANNEL

7

VOICE/

FAX

CHANNEL

3

VOICE/

FAX

CHANNEL

6

VOICE/

FAX

CHANNEL

2

VOICE/

FAX

CHANNEL

5

VOICE/

FAX

CHANNEL

1

CHANNEL 10

CHANNEL 9

CHANNEL 8

CHANNEL 7

CHANNEL 6

CHANNEL 5

CHANNEL 4

CHANNEL 3

CHANNEL 2 (RS232/V.35)

CHANNEL 1 (RS232/V.35)

10BASET

ETHERNET

COMMAND PORT

EXT. COMPOSITE LINK (RS232/V.35)

POWER

I

O

GND

T1 DSU

MONITOR

XMT RCV

INTERNAL

COMPOSITE

LINK

FXS

FXO

E&M

FXS

E&M

FXO

PSTN

Voice/Fax Channel 1 - 8
Connections

Figure 5. Voice/Fax Cable Connections

If you are connecting the station side of a telephone switch (PBX) to your MultiFRAD,
connect one end of an RJ-11 phone cord to the Voice/Fax Channel 1 FXO connector on the
back of the MultiFRAD and the other end to the phone jack.

If you are connecting an E&M trunk from a telephone switch to your MultiFRAD, connect one
end of an RJ-45 phone cord to the Voice/Fax Channel 1 E&M connector on the back of the
MultiFRAD and the other end to the trunk phone jack.

If you are connecting to an E&M trunk, you need to ensure that the E&M trunk jumper is in
the correct position for the E&M type trunk. The default E&M jumper position is E&M type 2.
To change the E&M jumper position, perform the E&M jumper block positioning procedure in
following this procedure.

7

Repeat the above step to connect the remaining telephone equipment to each Voice/Fax
Channel on your MultiFRAD.

8

Turn on power to the MultiFRAD by placing the On/Off switch on the back panel to the 1
position.

At this time your MultiFRAD is completely cabled. Proceed to the next section to load your
software.