OM-188 414 Page 11

4-4.

Troubleshooting

Trouble

Remedy

No weld output; wire does not feed.

Be sure line disconnect switch is On (see Section 2-8).

Replace building line fuse or reset circuit breaker if open (see Section 2-8).

Reset circuit breaker CB1 (see Section 4-2).

Secure gun trigger connections.

Check and replace Power switch if necessary.

No weld output; overload light on

Thermostat TP1 open (overheating). Allow fan to run; the thermostat will close when the unit has cooled
(see Section 2-2).

An overload condition occurred. Release gun trigger (see Section 4-3).

Low weld output.

Connect unit to proper input voltage or check for low line voltage (see Section 2-8).

No wire feed.

Reset circuit breaker CB1 (see Section 4-2).

Turn Wire Speed control to higher setting (see Section 3-1).

Clear obstruction in gun contact tip or liner.

Readjust drive roll pressure.

Change to correct size drive rolls (see Section 2-5).

Check gun trigger and leads. Repair or replace gun if necessary.

Have Factory Authorized Service Agent check main control board.

Poor weld bead, or welding
wire is noodle welding.

Check polarity setting for type of welding wire being used.