Value

Type

Description

POLARITY_TRIGGER

DWORD

(Optional) Defines the polarity (active “high” or “low”) of the
“Trigger” signal. Allowed values are 1 (normal polarity, active
“high”) and 0 (inverted polarity, active “low”). Default is 1 (normal
polarity, active “high”).

POLARITY_ILLUM

DWORD

(Optional) Defines the polarity (active “high” or “low”) of the
“Illum_ON” signal. Allowed values are 1 (normal polarity, active
“high”) and 0 (inverted polarity, active “low”). Default is 1 (normal
polarity, active “high”).

POLARITY_AIMER

DWORD

(Optional) Defines the polarity (active “high” or “low”) of the
“Aimer” signal. Allowed values are 1 (normal polarity, active
“high”) and 0 (inverted polarity, active “low”). Default is 1 (normal
polarity, active “high”).

PixelClock

DWORD

(Optional) Defines the image sensor pixel clock frequency, in
Hz. Allowed values are 12000000 Hz and 24000000 Hz. Default
is 24000000 Hz.

I2CBusClock

DWORD

(Optional) Defines the I

2

C bus transfer rate, in Hz. Allowed

values are 100000 Hz (standard mode) and 400000 Hz (fast
mode). Default is 400000 Hz (fast mode).

IntegrationTime

DWORD

(Optional) Defines the image integration (exposure) time, in
microseconds. Default is 8000 µs. In the snapshot mode, if
illumination is enabled, the image integration time equals the
maximum illumination time.

MinFlashTime

DWORD

(Optional) Defines the minimum illumination time for the
snapshot mode, in microseconds. Default is 0 µs.

IllumControl

DWORD

(Optional) Enables (value of 1) or disables (value of 0)
illumination. Default is 1 (illumination is enabled).

Gain1000

DWORD

(Optional) Defines the image sensor absolute gain multiplied by
1000. It ranges from 1000 (Gain = 1 or 0 dB) to 16000 (Gain =
16 or 24.08 dB). Default is 1000 (Gain = 1 or 0 dB).

ReverseRows

DWORD

(Optional) Defines order in which rows are transferred from the
image sensor: 0 is normal readout (from top to bottom) and 1 is
reversed readout (from bottom to top). Default is 0 (reversed
order).

ReverseCols

DWORD

(Optional) Defines order in which columns are transferred from
the image sensor: 0 is normal order (from left to right) and 1 is
reversed order (from right to left). Default is 0 (reversed order).

ImgWidth

DWORD

(Optional) Defines the image width (number of columns).
Default is 1280 columns.

ImgHeight

DWORD

(Optional) Defines the image height (number of rows).
Default is 960 rows.