Is4910, Ppendix, River – Metrologic Instruments IS4910 Series User Manual

Page 38: Nitialization

Advertising
background image

32

A

PPENDIX

B:

IS4910

D

RIVER

I

NITIALIZATION

F

ILE


Index

(optional) defines the instance number of the device and can be a single decimal digit starting

from 1 (first instance) to 9 (ninth instance) and 0 (tenth instance). The Index number is appended to the
VUQ prefix to construct the device name. Default is 1.

DLL

specifies the name of the DLL that implements the driver (vuqdrv.dll).


Path

specifies the full path to the DLL that implements the driver.


GPIO_CIF_FV

specifies the GPIO pin connected to the “VSYNC” signal.


GPIO_CIF_LV

specifies the GPIO pin connected to the “HSYNC” signal.


GPIO_CIF_PCLK

specifies the GPIO pin connected to the “PCLK” signal.


GPIO_CIF_DD#

specifies the GPIO pin connected to the “D#” signal


GPIO_TRIGGER

specifies the GPIO pin connected to the “Trigger” signal.


GPIO_ILLUM

(optional) specifies the GPIO pin connected to the “Illum_ON” signal. No default value.


GPIO_AIMER

(optional) specifies the GPIO pin connected to the “Aimer” signal. No default value.


POLARITY_TRIGGER

(optional) specifies the polarity (active “high” or “low”) of the “Trigger” signal.

Allowed values are 1 (normal polarity, active “high”) and 0 (inverted polarity, active “low”). Default is 1
(normal polarity, active “high”).

POLARITY_ILLUM

(optional) specifies the polarity (active “high” or “low”) of the “Illum_ON” signal.

Allowed values are 1 (normal polarity, active “high”) and 0 (inverted polarity, active “low”). Default is 1
(normal polarity, active “high”).

POLARITY_AIMER

(optional) specifies the polarity (active “high” or “low”) of the “Aimer” signal. Allowed

values are 1 (normal polarity, active “high”) and 0 (inverted polarity, active “low”). Default is 1 (normal
polarity, active “high”).

SysIntr

(optional) specifies the system interrupt number corresponding to the quick capture interface

IRQ. If it’s not defined the driver would request the IRQ-to-SYSINTR mapping.

DMAChannel

(optional) specifies the DMA channel to be used by the driver for DMA operations. If it’s not

defined then the first found free DMA channel would be used.

MaxMemFrames

(optional) specifies the maximum number of frames the image buffer can hold. Default is

4.

IntegrationTime

(optional) defines the image integration (exposure) time, in microseconds. Default is

8000 µs. In the snapshot mode, if illumination is enabled, the image integration time equals the maximum
illumination time.

MinFlashTime

(optional) defines the minimum illumination time for the snapshot mode, in

microseconds. Default is 0 µs.

IllumControl

(optional) enables (value of 1) or disables (value of 0) illumination. Default is 1

(illumination is enabled).