Miller Electric R-115 User Manual

Page 20

Advertising
background image

OM-193 471 Page 16

3-13. Connection For Hobart Welding Power Sources With 5-Socket And 115 Volt AC

Receptacles

Ref. 802 310 / Ref. 193 749

1

Terminal Block 1T

2

3-Conductor Cord

3

2-Conductor Cord

4

Green Lead (Connected To

Ground In Section 3-9)

Connect remaining leads to

terminal block as follows:
A: 115 VAC/Neutral Lead
B: 115 VAC/Hot Lead
C: No Connection
D: Dry Contact Closure w/Respect

To Terminal E Lead
E: 115 VAC/Contact Closure Lead

.

For welding power sources
requiring dry contact closure,

move lead 38 at terminal block

to terminal D.

Secure strain relief clamp around

cords.
Reinstall and secure wrapper to

unit.
Connect remaining cord ends to

welding power source.

Tools Needed:

1

A

B

C

D

E

3

1/4 in

2

4

E

A

B

C

D

.

Make ground lead connections
according to Section 3-9
before

following this procedure.

3-14. Connection For Lincoln Welding Power Sources With 14-Socket Receptacle

Ref. 802 310 / Ref. 193 749

1

Terminal Block 1T

2

Interconnecting Power Cord

3

Green Lead (Connected To

Ground In Section 3-9)

Connect remaining leads to

terminal block as follows:
A: 115 VAC/Neutral Lead
B: 115 VAC/Hot Lead
C: No Connection
D: Dry Contact Closure w/Respect

To Terminal E Lead
E: 115 VAC/Contact Closure Lead

.

For welding power sources
requiring dry contact closure,

move lead 38 at terminal block

to terminal D.

Secure strain relief clamp around

cord.
Reinstall and secure wrapper to

unit.
Connect remaining end of cord to

welding power source.

Tools Needed:

1

A

B

C

D

E

2

1/4 in

3

B

A

C

D

E

F

H

G

K

L

N

M

J

I

.

Make ground lead connections
according to Section 3-9
before

following this procedure.

Advertising