Miller Electric R-115 User Manual

Page 22

Advertising
background image

OM-193 471 Page 18

3-17. Connection For Welding Power Sources With Hubbell Receptacles

Ref. 802 310 / Ref. 193 749

1

Terminal Block 1T

2

Interconnecting Power Cord

3

Green Lead (Connected To

Ground In Section 3-9)

Connect remaining leads to

terminal block as follows:
A: 115 VAC/Neutral Lead
B: 115 VAC/Hot Lead
C: No Connection
D: No Connection
E: 115 VAC/Contact Closure Lead
Secure strain relief clamp around

cord.
Reinstall and secure wrapper to

unit.
Connect remaining end of cord to

welding power source.

Tools Needed:

1/4 in

1

A

B

C

D

E

2

3

.

Make ground lead connections
according to Section 3-9
before

following this procedure.

3-18. Connection For Miller Welding Power Sources With 14-Socket Receptacle

Ref. 802 310 / Ref. 193 749

1

Terminal Block 1T

2

Interconnecting Power Cord

3

White Lead

4

Black Lead

5

Red Lead

6

Green Lead (Connected To

Ground In Section 3-9)

Connect remaining leads to

terminal block as follows:
A: White Lead (115 VAC/Neutral)
B: Black Lead (115 VAC/Hot)
C: No Connection
D: No Connection
E: Red Lead (115 VAC/Contact

Closure)
Secure strain relief clamp around

cord.
Reinstall and secure wrapper to

unit.
Connect remaining end of cord to

welding power source.

Tools Needed:

1/4 in

1

A

B

C

D

E

2

5

6

4

3

A

J

B K

I

C L N

H

D M

G

E F

.

Make ground lead connections
according to Section 3-9
before

following this procedure.

Advertising