40

Command:

&Q

n Sync/Async Mode

Values:

n = 0–3, 5, 6

Default:

5

Description:

This command is an extension of the &M command, and is used
to control which connection modes are permitted. It is used in
conjunction with S36 and S48. (See also the \N command.)

&Q0 Selects direct asynchronous operation. See &M0.
&Q1 Selects synchronous connect mode with asynchronous offline

command mode. See &M1. (Serial interface operation only.)

&Q2 Selects synchronous connect mode with asynchronous offline

command mode and enables DTR dialing of directory 3. See
&M2

. (Serial interface operation only.)

&Q3 Selects synchronous connect mode with asynchronous offline

command mode and enables DTR to act as a talk/data switch.
See &M3. (Serial interface operation only.)

&Q5 The modem will try to negotiate an error-corrected link. The

modem can be configured using S36 to determine whether a
failure will result in the modem disconnecting or falling back
to a non-error-correction connection. See also \N3.

&Q6 Selects asynchronous operation with speed buffering and no

error correction. Same as \N0.

Command:

&R

n Clear to Send (CTS) Control

Values:

n = 0 or 1

Default:

1

Description:

&R0

Let the CTS state follow the RTS state when online..

&R1

Force CTS high (ON).

Command:

&S

n

Data Set Ready (DSR) Control

Values:

n = 0 or 1

Default:

0

Description:

&S0

Force DSR high (on) at all times.

&S1

Let DSR go high only during a connection.

Command:

&T

n

V.54 Test Commands

Values:

n = 0, 1, 3, 4, 5, 6, 7, or 8

Default:

None

Description:

The modem can perform selected test and diagnostic functions. A
test can be run only when the modem is in asynchronous op-
eration in non-error-correction mode (normal or direct mode).
For tests 3, 6, and 7, a connection between the two modems
must first be established. To terminate a test in progress, the
escape sequence (+++) must be entered first, except for param-
eters 7 and 8. If S18 is non-zero, a test terminates automatically
after the time specified by S18 and displays the OK message.

&T0

Abort. Stop any test in progress.

&T1

Start local analog loopback, V.54 Loop 3. If a connection exists
when this command is issued, the modem hangs up. A CON-
NECT message is displayed at the start of the test.

&T3

Start local digital loopback, V.54 Loop 2. If no connection exists,
ERROR is returned.

Advertising